{"id":4953,"date":"2023-05-30T11:04:58","date_gmt":"2023-05-30T09:04:58","guid":{"rendered":"https:\/\/ecosens.aretis-staging.ch\/referenz\/glatttower-wallisellen-copy-2\/"},"modified":"2024-03-05T15:39:59","modified_gmt":"2024-03-05T14:39:59","slug":"investigation-air-quality-center-schluefweg","status":"publish","type":"referenz","link":"https:\/\/www.ecosens.ch\/en\/reference\/investigation-air-quality-center-schluefweg\/","title":{"rendered":"Investigation of air quality and ventilation hygiene, Kloten"},"featured_media":4955,"template":"","kategorie":[69,77],"class_list":["post-4953","referenz","type-referenz","status-publish","has-post-thumbnail","hentry","kategorie-gebaeude","kategorie-raumluft-wohngifte-radon"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten - Ecosens AG<\/title>\n<meta name=\"description\" content=\"Das Zentrum Schluefweg in Kloten verf\u00fcgt \u00fcber ein weitverzweigtes L\u00fcftungsanlagennetz aus der Erstellungszeit, welches in den n\u00e4chsten Jahren etappenweise erneuert wird. Um sicherzustellen, dass von der L\u00fcftungsanlage im aktuellen Zustand keine Gesundheitsrisiko f\u00fcr die Geb\u00e4udenutzer ausgeht, wurde durch die Ecosens AG die Qualit\u00e4t der Luft aus der L\u00fcftungsanlage untersucht. Dazu wurde diese Zuluft in diversen R\u00e4umen auf allf\u00e4llige mikrobielle Kontaminationen, Feinstaub und das Vorhandensein von k\u00fcnstlichen Mineralfasern \u00fcberpr\u00fcft und diese Messwerte mit den hygienischen Anforderungen der g\u00fcltigen Normen und Richtlinien verglichen. Gem\u00e4ss den Hygieneanforderungen an raumluft\u00adtechnische Anlagen und Ger\u00e4te darf die Qualit\u00e4t der Zuluft nicht schlechter sein, als die entsprechende Vergleichsluft (in diesem Fall die Aussenluft). Mit den durchgef\u00fchrten Messungen konnte gezeigt werden, dass die Qualit\u00e4t der Luft aus den L\u00fcftungsanlage aus hygienischer Sicht einwandfrei ist und eine Gef\u00e4hrdung von Geb\u00e4ude\u00adnutzer somit ausgeschlossen werden kann.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ecosens.ch\/en\/reference\/investigation-air-quality-center-schluefweg\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten - Ecosens AG\" \/>\n<meta property=\"og:description\" content=\"Das Zentrum Schluefweg in Kloten verf\u00fcgt \u00fcber ein weitverzweigtes L\u00fcftungsanlagennetz aus der Erstellungszeit, welches in den n\u00e4chsten Jahren etappenweise erneuert wird. Um sicherzustellen, dass von der L\u00fcftungsanlage im aktuellen Zustand keine Gesundheitsrisiko f\u00fcr die Geb\u00e4udenutzer ausgeht, wurde durch die Ecosens AG die Qualit\u00e4t der Luft aus der L\u00fcftungsanlage untersucht. Dazu wurde diese Zuluft in diversen R\u00e4umen auf allf\u00e4llige mikrobielle Kontaminationen, Feinstaub und das Vorhandensein von k\u00fcnstlichen Mineralfasern \u00fcberpr\u00fcft und diese Messwerte mit den hygienischen Anforderungen der g\u00fcltigen Normen und Richtlinien verglichen. Gem\u00e4ss den Hygieneanforderungen an raumluft\u00adtechnische Anlagen und Ger\u00e4te darf die Qualit\u00e4t der Zuluft nicht schlechter sein, als die entsprechende Vergleichsluft (in diesem Fall die Aussenluft). Mit den durchgef\u00fchrten Messungen konnte gezeigt werden, dass die Qualit\u00e4t der Luft aus den L\u00fcftungsanlage aus hygienischer Sicht einwandfrei ist und eine Gef\u00e4hrdung von Geb\u00e4ude\u00adnutzer somit ausgeschlossen werden kann.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ecosens.ch\/en\/reference\/investigation-air-quality-center-schluefweg\/\" \/>\n<meta property=\"og:site_name\" content=\"Ecosens AG\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-05T14:39:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"405\" \/>\n\t<meta property=\"og:image:height\" content=\"291\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/\",\"url\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/\",\"name\":\"Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten - Ecosens AG\",\"isPartOf\":{\"@id\":\"https:\/\/www.ecosens.ch\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg\",\"datePublished\":\"2023-05-30T09:04:58+00:00\",\"dateModified\":\"2024-03-05T14:39:59+00:00\",\"description\":\"Das Zentrum Schluefweg in Kloten verf\u00fcgt \u00fcber ein weitverzweigtes L\u00fcftungsanlagennetz aus der Erstellungszeit, welches in den n\u00e4chsten Jahren etappenweise erneuert wird. Um sicherzustellen, dass von der L\u00fcftungsanlage im aktuellen Zustand keine Gesundheitsrisiko f\u00fcr die Geb\u00e4udenutzer ausgeht, wurde durch die Ecosens AG die Qualit\u00e4t der Luft aus der L\u00fcftungsanlage untersucht. Dazu wurde diese Zuluft in diversen R\u00e4umen auf allf\u00e4llige mikrobielle Kontaminationen, Feinstaub und das Vorhandensein von k\u00fcnstlichen Mineralfasern \u00fcberpr\u00fcft und diese Messwerte mit den hygienischen Anforderungen der g\u00fcltigen Normen und Richtlinien verglichen. Gem\u00e4ss den Hygieneanforderungen an raumluft\u00adtechnische Anlagen und Ger\u00e4te darf die Qualit\u00e4t der Zuluft nicht schlechter sein, als die entsprechende Vergleichsluft (in diesem Fall die Aussenluft). Mit den durchgef\u00fchrten Messungen konnte gezeigt werden, dass die Qualit\u00e4t der Luft aus den L\u00fcftungsanlage aus hygienischer Sicht einwandfrei ist und eine Gef\u00e4hrdung von Geb\u00e4ude\u00adnutzer somit ausgeschlossen werden kann.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage\",\"url\":\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg\",\"contentUrl\":\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg\",\"width\":405,\"height\":291},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.ecosens.ch\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ecosens.ch\/#website\",\"url\":\"https:\/\/www.ecosens.ch\/\",\"name\":\"Ecosens AG\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.ecosens.ch\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ecosens.ch\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ecosens.ch\/#organization\",\"name\":\"Ecosens AG\",\"url\":\"https:\/\/www.ecosens.ch\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ecosens.ch\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/01\/logo.svg\",\"contentUrl\":\"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/01\/logo.svg\",\"width\":226,\"height\":45,\"caption\":\"Ecosens AG\"},\"image\":{\"@id\":\"https:\/\/www.ecosens.ch\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Investigation of air quality and ventilation hygiene, Kloten - Ecosens AG","description":"The Schluefweg Center in Kloten has an extensive network of ventilation systems dating from the time it was built, which will be replaced in stages over the next few years. To ensure that the ventilation system in its current state does not pose a health risk to building users, Ecosens AG examined the quality of the air from the ventilation system. To this end, this supply air was checked in various rooms for any microbial contamination, fine dust and the presence of artificial mineral fibers and these measured values were compared with the hygiene requirements of the applicable standards and guidelines. According to the hygiene requirements for ventilation systems and devices, the quality of the supply air must not be worse than the corresponding reference air (in this case the outside air). The measurements carried out showed that the quality of the air from the ventilation system is flawless from a hygienic point of view and that any risk to building users can therefore be ruled out.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ecosens.ch\/en\/reference\/investigation-air-quality-center-schluefweg\/","og_locale":"en_US","og_type":"article","og_title":"Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten - Ecosens AG","og_description":"Das Zentrum Schluefweg in Kloten verf\u00fcgt \u00fcber ein weitverzweigtes L\u00fcftungsanlagennetz aus der Erstellungszeit, welches in den n\u00e4chsten Jahren etappenweise erneuert wird. Um sicherzustellen, dass von der L\u00fcftungsanlage im aktuellen Zustand keine Gesundheitsrisiko f\u00fcr die Geb\u00e4udenutzer ausgeht, wurde durch die Ecosens AG die Qualit\u00e4t der Luft aus der L\u00fcftungsanlage untersucht. Dazu wurde diese Zuluft in diversen R\u00e4umen auf allf\u00e4llige mikrobielle Kontaminationen, Feinstaub und das Vorhandensein von k\u00fcnstlichen Mineralfasern \u00fcberpr\u00fcft und diese Messwerte mit den hygienischen Anforderungen der g\u00fcltigen Normen und Richtlinien verglichen. Gem\u00e4ss den Hygieneanforderungen an raumluft\u00adtechnische Anlagen und Ger\u00e4te darf die Qualit\u00e4t der Zuluft nicht schlechter sein, als die entsprechende Vergleichsluft (in diesem Fall die Aussenluft). Mit den durchgef\u00fchrten Messungen konnte gezeigt werden, dass die Qualit\u00e4t der Luft aus den L\u00fcftungsanlage aus hygienischer Sicht einwandfrei ist und eine Gef\u00e4hrdung von Geb\u00e4ude\u00adnutzer somit ausgeschlossen werden kann.","og_url":"https:\/\/www.ecosens.ch\/en\/reference\/investigation-air-quality-center-schluefweg\/","og_site_name":"Ecosens AG","article_modified_time":"2024-03-05T14:39:59+00:00","og_image":[{"width":405,"height":291,"url":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/","url":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/","name":"Investigation of air quality and ventilation hygiene, Kloten - Ecosens AG","isPartOf":{"@id":"https:\/\/www.ecosens.ch\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage"},"image":{"@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg","datePublished":"2023-05-30T09:04:58+00:00","dateModified":"2024-03-05T14:39:59+00:00","description":"The Schluefweg Center in Kloten has an extensive network of ventilation systems dating from the time it was built, which will be replaced in stages over the next few years. To ensure that the ventilation system in its current state does not pose a health risk to building users, Ecosens AG examined the quality of the air from the ventilation system. To this end, this supply air was checked in various rooms for any microbial contamination, fine dust and the presence of artificial mineral fibers and these measured values were compared with the hygiene requirements of the applicable standards and guidelines. According to the hygiene requirements for ventilation systems and devices, the quality of the supply air must not be worse than the corresponding reference air (in this case the outside air). The measurements carried out showed that the quality of the air from the ventilation system is flawless from a hygienic point of view and that any risk to building users can therefore be ruled out.","breadcrumb":{"@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#primaryimage","url":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg","contentUrl":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/05\/Bild_Lueftung_Kloten-55ccbabc.jpg","width":405,"height":291},{"@type":"BreadcrumbList","@id":"https:\/\/www.ecosens.ch\/referenz\/untersuchung-luftqualitaet-zentrum-schluefweg\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.ecosens.ch\/"},{"@type":"ListItem","position":2,"name":"Untersuchung Luftqualit\u00e4t und L\u00fcftungshygiene, Kloten"}]},{"@type":"WebSite","@id":"https:\/\/www.ecosens.ch\/#website","url":"https:\/\/www.ecosens.ch\/","name":"Ecosens AG","description":"","publisher":{"@id":"https:\/\/www.ecosens.ch\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ecosens.ch\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ecosens.ch\/#organization","name":"Ecosens AG","url":"https:\/\/www.ecosens.ch\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ecosens.ch\/#\/schema\/logo\/image\/","url":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/01\/logo.svg","contentUrl":"https:\/\/www.ecosens.ch\/wp-content\/uploads\/2023\/01\/logo.svg","width":226,"height":45,"caption":"Ecosens AG"},"image":{"@id":"https:\/\/www.ecosens.ch\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/referenz\/4953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/referenz"}],"about":[{"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/types\/referenz"}],"version-history":[{"count":5,"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/referenz\/4953\/revisions"}],"predecessor-version":[{"id":9119,"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/referenz\/4953\/revisions\/9119"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/media\/4955"}],"wp:attachment":[{"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/media?parent=4953"}],"wp:term":[{"taxonomy":"kategorie","embeddable":true,"href":"https:\/\/www.ecosens.ch\/en\/wp-json\/wp\/v2\/kategorie?post=4953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}